An Open Workspace, Configured Around Your Team
The Antaly 40ft Expandable Container Office provides an open-plan interior for desks, collaborative work areas, and day-to-day project coordination. Its expandable structure travels in a folded configuration before opening into a wider footprint at the installation site.
Start with an open workspace or discuss a layout with meeting rooms, private offices, a kitchenette, or a bathroom. Each configuration can be reviewed around your team's working arrangements, site conditions, and utility requirements.
Consider this modular office for construction projects, satellite operations, event management, or field coordination. Confirm the approved layout, included equipment, and installation requirements before ordering.
Key Features
-
Open-Plan Interior: Arrange desks, storage, and shared work zones around the approved floor plan.
-
Optional Partitioned Spaces: Discuss enclosed offices, meeting rooms, or reception areas.
-
Optional Kitchenette and Bathroom: Add facilities according to the selected package and available site utilities.
-
Expandable Structure: Delivered in a folded configuration and opened at the installation site.
-
Protected Steel Frame: Specified with an electrostatic-sprayed coating and anti-corrosion treatment.
-
Window and Finish Options: Select glazing, frames, interior wall finishes, and flooring to suit the project.
-
Project-Specific Utility Planning: Confirm electrical outlets, lighting, data routes, plumbing, and HVAC provisions before production.
Dimensions
Approximate dimensions supplied for the 40ft expandable office configuration.
| Configuration |
Length × Width × Height |
| Expanded Exterior |
38' 9" × 20' 5" × 8' 2" |
| Interior |
37' 10" × 19' 11" × 7' 3" |
| Folded Exterior |
38' 9" × 7' 3" × 8' 2" |
Confirm dimensions against the approved drawings for the selected configuration. Partitions, facilities, and finishes affect usable workspace. Request verified floor area, clear ceiling heights, shipping weight, and transport dimensions before ordering.
Choose Your Office Layout
Open-Plan Workspace
The base layout provides an unpartitioned work area that can be planned for individual desks, shared tables, storage, and circulation. Confirm workstation capacity against furniture dimensions, exit routes, ventilation, and applicable occupancy requirements.
Private Offices and Meeting Rooms
Discuss partitions for enclosed offices, a conference room, or a visitor reception area. Partition locations affect daylight, access, utility routing, and the remaining open workspace.
Optional Kitchenette
A kitchenette can be specified with the agreed cabinetry, countertop, sink, and appliance provisions. Confirm water supply, drainage, electrical requirements, and included equipment in the quotation.
Optional Bathroom
A bathroom can be discussed where site utilities and local requirements allow. Fixture options may include a toilet, wash basin, mirror cabinet, and, where specified, a shower with a textured-glass partition.
Bathroom fixtures, finishes, ventilation, hot-water equipment, and plumbing connections are optional unless expressly included in the order.
Construction Specifications
| Component |
Supplied Specification |
| Wall Panels |
Type 950, 65 mm EPS composite panels with 0.3 mm steel facings on both sides |
| Frame Finish |
Electrostatic-sprayed protective coating and anti-corrosion treatment |
| Folding Hinges |
130 mm galvanized embedded hinges |
| Floor System |
18 mm bamboo board substrate with 4 mm SPC flooring |
| Main Roof Panels |
Type 950, 50 mm EPS steel composite panels with 0.45 mm corrugated outer sheet |
| Ceiling Panels |
Type 950, 50 mm EPS steel composite panels |
| Wing Roof Panels |
Type 950, 65 mm EPS steel composite panels with 0.45 mm corrugated outer sheet |
| Windows |
Proposed aluminum alloy double-glazed sliding windows; alternative frames subject to quotation |
| Electrical |
Standard wiring, with project-specific requirements subject to confirmation |
Confirm these specifications for the selected office configuration. Material descriptions alone do not establish fire classifications, insulation ratings, acoustic performance, or wind and snow-load capacity. Request applicable test reports and engineering documentation.
Doors, Windows, and Access
Discuss entrance doors, window placement, glazing, locks, and hardware around the intended office use. Available selections may include aluminum alloy or thermally broken aluminum frames with double glazing, selected security doors, and interior partition doors.
Confirm required exit arrangements, door clearances, safety glazing, accessible entrances, and circulation routes against local commercial occupancy requirements.
Interior Finish Options
Wall Panels
- Beige
- Fine Fabric
- Sub-Gray Country
- Fine Pearl
- Boutique Hot Stamping
- Wenge Wood A009 – Double Inclined Groove
- A003 Dashan Wood
SPC Flooring
-
4 mm Options: HY8911, HY8918, HY8920, HY8915, and HY8921.
-
8 mm Options: F8581, F8582, F8583, F8585, and F8586, subject to quotation.
Request current samples and confirm availability, suitability for the intended use, and any upgrade costs.
Electrical, Data, and Climate Control
Plan outlets, lighting, and electrical loads around your workstation and equipment arrangement. Confirm supply voltage, frequency, circuit protection, and required electrical compliance before manufacturing.
Discuss data cabling routes, network equipment locations, and HVAC provisions separately. Internet service, active network equipment, heating, and cooling systems are included only when listed in the quotation.
Ventilation and climate-control requirements depend on local conditions, occupancy, glazing, and the selected building assembly.
Potential Applications
- Construction site administration and project coordination
- Corporate satellite or project offices
- Event operations and coordination centers
- Press and media workspaces
- Emergency response or NGO field coordination
- Farm, industrial, or logistics site administration
Each application is subject to site suitability, permitted use, and applicable building, fire safety, accessibility, and workplace requirements.
Delivery and Site Installation
Before delivery, confirm transport access, unloading space, required equipment, and the prepared foundation or supporting surface. Follow the approved instructions for unfolding, positioning, securing, weather sealing, and anchoring.
Installation time depends on site readiness, the selected configuration, equipment, and labor requirements. Opening the structure does not mean it is ready for occupancy; utility connections, testing, and required inspections must also be completed.
Confirm local wind, snow, seismic, drainage, and foundation requirements before purchase.
Relocation and Multi-Unit Projects
For projects that may require future relocation, request the manufacturer's procedures for utility disconnection, folding, lifting, transport, and reinstallation.
Discuss multiple offices for larger operational sites. Module connections, shared services, or stacked configurations require separate design approval; stacking capability is not assumed for this model.
What's Included
The proposed base package includes the 40ft expandable office structure, specified installed exterior doors and windows, and an open-plan interior configuration.
Confirm the supplied finishes, flooring, wiring, lighting, and technical documents in an itemized quotation. Private offices, meeting-room partitions, kitchenette facilities, bathroom facilities, and their utility provisions are optional unless expressly included.
The approved drawings and signed quotation determine all included items. Office furniture, appliances, HVAC, network equipment, foundations, permits, engineering, delivery, unloading, installation, and utility connections must be confirmed separately.
Technical Documentation and Customization
Request the floor plan, 3D view, and roof and elevation drawings for the selected office layout. Discuss any additional structural, electrical, or permit documentation required for your site.
Customize partitions, finishes, doors, windows, facilities, and equipment provisions subject to design review and quotation. Standard product documents do not replace site-specific engineering or local approval where required.
Order Process
-
Share Your Requirements: Provide the site location, intended use, team needs, and quantity.
-
Select the Layout: Choose an open workspace or discuss partitions and optional facilities.
-
Approve the Specification: Confirm drawings, finishes, utility provisions, included items, and site responsibilities.
-
Arrange Delivery: Agree on the production schedule, transport, unloading, and installation arrangements.
-
Complete Site Work: Finish anchoring, connections, testing, and required approvals before use.
Plan Your Workspace with Antaly
Build your office configuration around the way your team works.
Contact Antaly for open-plan office layouts, optional facilities, pricing, delivery details, and multi-unit quotations.