{"product_id":"antaly-40ft-expandable-modular-office-flexible-workspace-with-bathroom","title":"40ft Expandable Modular Office – Flexible Workspace with Bathroom","description":"\u003cdiv class=\"antaly-product-description\"\u003e\n  \u003ch2\u003eA Workspace That Adapts to Your Operation.\u003c\/h2\u003e\n  \u003cp\u003eThe \u003cstrong\u003eAntaly 40ft Expandable Modular Office\u003c\/strong\u003e combines flexible workspace, a dedicated bathroom area, and specified electrical and plumbing infrastructure in one expandable structure. Plan the interior around shared workstations, private offices, meetings, or day-to-day site administration.\u003c\/p\u003e\n  \u003cp\u003eDelivered in a folded configuration and opened into a wider footprint on site, this office offers a modular option for worksite facilities, satellite teams, and temporary workspace expansion. The final layout, equipment package, and installation requirements are coordinated around your project.\u003c\/p\u003e\n\n  \u003ch2\u003eKey Features\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFlexible Office Layout:\u003c\/strong\u003e Discuss open work areas, private offices, meeting space, and staff facilities.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDedicated Bathroom Area:\u003c\/strong\u003e The proposed package includes a shower, wash basin, and toilet, subject to quotation.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eExpandable Structure:\u003c\/strong\u003e A folded transport configuration that opens into a wider workspace on site.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eElectrical and Plumbing Provisions:\u003c\/strong\u003e Confirm the supplied wiring, lighting, and plumbing points for your selected package.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDouble-Glazed Window Options:\u003c\/strong\u003e Coordinate glazing, opening styles, and window positions with the approved design.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProtected Steel Frame:\u003c\/strong\u003e Specified with an electrostatic-sprayed coating and anti-corrosion treatment.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFinish Selections:\u003c\/strong\u003e Choose from available wall finishes, flooring, exterior colors, doors, and windows.\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch2\u003eConfigure the Interior Around Your Team\u003c\/h2\u003e\n  \u003ch3\u003eOpen Work Area\u003c\/h3\u003e\n  \u003cp\u003eArrange desks, shared tables, and storage around your team's workflow. Review circulation, workstation clearances, power distribution, and access to the bathroom against the approved floor plan.\u003c\/p\u003e\n\n  \u003ch3\u003ePrivate Offices and Meeting Space\u003c\/h3\u003e\n  \u003cp\u003eDiscuss partitions for enclosed offices or a meeting room where the layout allows. Confirm partition materials, door positions, ventilation, lighting, and any acoustic requirements before approving the design.\u003c\/p\u003e\n\n  \u003ch3\u003eStaff and Support Areas\u003c\/h3\u003e\n  \u003cp\u003eA break area, storage zone, or kitchenette may be considered as part of a revised layout. Additional cabinetry, sinks, appliances, and utility provisions are subject to design review and quotation.\u003c\/p\u003e\n\n  \u003ch2\u003eBathroom Configuration\u003c\/h2\u003e\n  \u003cp\u003eThe proposed bathroom package includes a shower, wash basin, mirror cabinet, and toilet, with a textured-glass partition for wet and dry separation.\u003c\/p\u003e\n  \u003cp\u003eSpecified finish details include UV wall panels, SPC flooring, an insulated base, and protective underside components. Confirm fixture models, waterproofing details, ventilation, hot-water equipment, and the extent of factory-installed plumbing.\u003c\/p\u003e\n  \u003cp\u003eBathroom size, access, and fixture arrangements must be reviewed against the intended occupancy and applicable accessibility requirements. An accessible restroom configuration is not assumed.\u003c\/p\u003e\n\n  \u003ch2\u003eDimensions\u003c\/h2\u003e\n  \u003ctable\u003e\n    \u003ccaption\u003eApproximate dimensions supplied for this office configuration.\u003c\/caption\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth scope=\"col\"\u003eConfiguration\u003c\/th\u003e\n        \u003cth scope=\"col\"\u003eLength × Width × Height\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003cth scope=\"row\"\u003eExpanded Exterior\u003c\/th\u003e\n        \u003ctd\u003e38' 9\" × 20' 5\" × 8' 2\"\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003cth scope=\"row\"\u003eInterior\u003c\/th\u003e\n        \u003ctd\u003e37' 10\" × 19' 11\" × 7' 3\"\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n  \u003cp\u003e\u003csmall\u003eConfirm all dimensions and clear ceiling heights against the approved drawings. Partitions, bathroom facilities, finishes, and equipment reduce available workspace. Request verified floor area, folded transport dimensions, and shipping weight before ordering.\u003c\/small\u003e\u003c\/p\u003e\n\n  \u003ch2\u003eConstruction Specifications\u003c\/h2\u003e\n  \u003ctable\u003e\n    \u003cthead\u003e\n      \u003ctr\u003e\n        \u003cth scope=\"col\"\u003eComponent\u003c\/th\u003e\n        \u003cth scope=\"col\"\u003eSupplied Specification\u003c\/th\u003e\n      \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n      \u003ctr\u003e\n        \u003cth scope=\"row\"\u003eWall Panels\u003c\/th\u003e\n        \u003ctd\u003eType 950, 65 mm EPS composite panels with 0.3 mm steel facings on both sides\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003cth scope=\"row\"\u003eFrame Finish\u003c\/th\u003e\n        \u003ctd\u003eElectrostatic-sprayed protective coating and anti-corrosion treatment\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003cth scope=\"row\"\u003eFolding Hinges\u003c\/th\u003e\n        \u003ctd\u003e130 mm galvanized embedded hinges\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003cth scope=\"row\"\u003eFloor System\u003c\/th\u003e\n        \u003ctd\u003e18 mm bamboo board substrate with 4 mm SPC flooring\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003cth scope=\"row\"\u003eMain Roof Panels\u003c\/th\u003e\n        \u003ctd\u003eType 950, 50 mm EPS steel composite panels with 0.45 mm corrugated outer sheet\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003cth scope=\"row\"\u003eCeiling Panels\u003c\/th\u003e\n        \u003ctd\u003eType 950, 50 mm EPS steel composite panels\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003cth scope=\"row\"\u003eWing Roof Panels\u003c\/th\u003e\n        \u003ctd\u003eType 950, 65 mm EPS steel composite panels with 0.45 mm corrugated outer sheet\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003cth scope=\"row\"\u003eWindows\u003c\/th\u003e\n        \u003ctd\u003eProposed aluminum alloy double-glazed sliding windows; alternative frames subject to quotation\u003c\/td\u003e\n      \u003c\/tr\u003e\n      \u003ctr\u003e\n        \u003cth scope=\"row\"\u003eElectrical\u003c\/th\u003e\n        \u003ctd\u003eStandard wiring, with project-specific requirements subject to confirmation\u003c\/td\u003e\n      \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n  \u003c\/table\u003e\n  \u003cp\u003e\u003csmall\u003eSpecifications must be confirmed for the selected office model. Material descriptions alone do not establish fire classifications, acoustic ratings, insulation performance, or wind and snow-load capacity. Request applicable engineering and test documentation for the installation location.\u003c\/small\u003e\u003c\/p\u003e\n\n  \u003ch2\u003eDoors, Windows, and Interior Finishes\u003c\/h2\u003e\n  \u003cp\u003eAvailable selections may include metal entrance doors, thermally broken aluminum frames, double-glazed windows, and interior doors suited to the agreed partitions. Confirm locks, hardware, safety glazing, opening sizes, and required exit arrangements.\u003c\/p\u003e\n\n  \u003ch3\u003eWall Finish Options\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003eBeige\u003c\/li\u003e\n    \u003cli\u003eFine Fabric\u003c\/li\u003e\n    \u003cli\u003eSub-Gray Country\u003c\/li\u003e\n    \u003cli\u003eFine Pearl\u003c\/li\u003e\n    \u003cli\u003eBoutique Hot Stamping\u003c\/li\u003e\n    \u003cli\u003eWenge Wood A009 — Double Inclined Groove\u003c\/li\u003e\n    \u003cli\u003eA003 Dashan Wood\u003c\/li\u003e\n  \u003c\/ul\u003e\n\n  \u003ch3\u003eSPC Flooring Options\u003c\/h3\u003e\n  \u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003e4 mm:\u003c\/strong\u003e HY8911, HY8918, HY8920, HY8915, and HY8921.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003e8 mm:\u003c\/strong\u003e F8581, F8582, F8583, F8585, and F8586, subject to quotation.\u003c\/li\u003e\n  \u003c\/ul\u003e\n  \u003cp\u003eRequest current samples and confirm exterior colors, finish availability, and upgrade costs. Product images may show optional layouts, furniture, or equipment not included in the base package.\u003c\/p\u003e\n\n  \u003ch2\u003eElectrical, Connectivity, and Climate Control\u003c\/h2\u003e\n  \u003cp\u003eConfirm supply voltage, frequency, circuit protection, lighting, outlet locations, and electrical loads for computers, office equipment, and other devices.\u003c\/p\u003e\n  \u003cp\u003eDiscuss data cabling, internet service, heating, cooling, and ventilation separately. These systems are included only when specified in the quotation, and their requirements depend on occupancy, equipment loads, climate, and the final building assembly.\u003c\/p\u003e\n  \u003cp\u003eRemote or off-grid operation requires separately designed power, water, wastewater, and communications arrangements. Pre-installed wiring and plumbing do not make the office operational without suitable site services.\u003c\/p\u003e\n\n  \u003ch2\u003ePotential Applications\u003c\/h2\u003e\n  \u003cul\u003e\n    \u003cli\u003eConstruction and remote worksite administration\u003c\/li\u003e\n    \u003cli\u003eSatellite offices and temporary workspace expansion\u003c\/li\u003e\n    \u003cli\u003eShared workspaces, subject to the approved layout\u003c\/li\u003e\n    \u003cli\u003eEvent administration and media coordination\u003c\/li\u003e\n    \u003cli\u003eNGO field offices and response coordination projects\u003c\/li\u003e\n  \u003c\/ul\u003e\n  \u003cp\u003eSuitability depends on local planning, commercial occupancy, fire safety, accessibility, sanitation, and structural requirements. Temporary placement does not automatically remove permit or approval obligations.\u003c\/p\u003e\n\n  \u003ch2\u003eWhat's Included\u003c\/h2\u003e\n  \u003cp\u003eThe proposed package includes the 40ft expandable office structure, specified installed doors and windows, the agreed interior framing and bathroom arrangement, and listed wiring, lighting, and plumbing points.\u003c\/p\u003e\n  \u003cp\u003eConfirm partitions, completed finishes, bathroom fixtures, cabinetry, and equipment in an itemized quotation.\u003c\/p\u003e\n  \u003cp\u003e\u003cstrong\u003eThe approved drawings and signed quotation determine all included items.\u003c\/strong\u003e Desks, chairs, office equipment, appliances, data systems, HVAC, hot-water equipment, off-grid systems, delivery, unloading, foundations, installation, site connections, engineering, and permits are included only when expressly listed.\u003c\/p\u003e\n\n  \u003ch2\u003eDelivery and Installation\u003c\/h2\u003e\n  \u003cp\u003eBefore delivery, confirm vehicle access, unloading space, handling equipment, and the required foundation or supporting system. Follow the approved instructions for positioning, unfolding, securing, weather sealing, and anchoring.\u003c\/p\u003e\n  \u003cp\u003eInstallation time depends on site readiness, equipment, labor, and the selected package. Opening the structure is only one stage; utility connections, testing, finishing work, and required inspections must be completed before use.\u003c\/p\u003e\n\n  \u003ch2\u003eTechnical Documents and Project Planning\u003c\/h2\u003e\n  \u003cp\u003eRequest the office-specific floor plan, 3D view, roof plan, and elevations for the configuration being ordered. Residential floor plans should not be treated as final office drawings.\u003c\/p\u003e\n  \u003cp\u003eReview workstation capacity, exits, circulation, bathroom access, ventilation, utility loads, and site requirements before approving the design. Standard product documents do not replace site-specific engineering or permit documentation where required.\u003c\/p\u003e\n\n  \u003ch2\u003eBuild Your Workspace Plan with Antaly\u003c\/h2\u003e\n  \u003cp\u003eShare your site location, team size, preferred layout, utility requirements, and order quantity to begin planning.\u003c\/p\u003e\n  \u003cp\u003e\u003cstrong\u003eContact Antaly for office layouts, finish selections, detailed specifications, and a tailored project quotation.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Antaly","offers":[{"title":"Default Title","offer_id":67773974380653,"sku":null,"price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0738\/2096\/2925\/files\/antaly-40ft-expandable-modular-office6_43eb91a7-f8e0-4774-b1a4-c7769c7db8d5.png?v=1792249738","url":"https:\/\/antaly.com.au\/products\/antaly-40ft-expandable-modular-office-flexible-workspace-with-bathroom","provider":"Antaly Australia","version":"1.0","type":"link"}